Inspections and testing

Electrical inspections for commercial and industrial sites

A structured inspection and test of your installation, with a written report that ranks what needs doing and when.

A commercial electrical inspection is a structured check of a building's fixed electrical installation: switchboards, wiring, protection, earthing and fittings. Phase Safe Electrical inspects and tests commercial and industrial installations for property owners, facilities managers and site managers across New Zealand, from bases in Wellington and Auckland. You receive a written report that ranks each defect by urgency, and our electricians can fix what we find.

What does a commercial electrical inspection check?

An electrical inspection checks that the fixed installation is undamaged, has not deteriorated, and has no dangerous defects, so it is safe to keep using. It starts with a visual inspection of switchboards, cables, fittings and earthing, and adds testing where needed, from tests with the power on to full testing with circuits isolated. The scope is agreed before we start, so you know what the report will cover.

Insurer risk guidance describes three levels, and we use the same structure to agree the scope:

Level What it involves Power off?
Visual inspection Switchboards, cables, fittings and earthing checked for damage, overheating and wear No
Visual plus limited testing Adds earth continuity, bonding, polarity and RCD tests Mostly no
Visual plus full testing Adds insulation resistance, earth fault loop impedance and protective device checks Yes, in planned sections

Signs of overheating, arcing or poor connections are a reason to move to testing. Where switchboards are the main concern, a switchboard survey looks at every board in more depth.

Is an electrical inspection legally required for a commercial building?

For most commercial buildings there is no fixed legal interval for a general electrical inspection. The duty is broader: under the Electricity (Safety) Regulations 2010, an owner or operator must not use, or let anyone else use, an installation that is electrically unsafe. The Health and Safety at Work Act 2015 also requires a business to keep its workplace and plant without risks so far as is reasonably practicable.

Some installations do have set periodic assessments under regulation 75, including caravan parks, marinas, construction sites and electrical installations in hazardous areas. If your site stores or uses flammable gas, liquids or combustible dust, see our hazardous area inspections.

Two other rules often trigger an inspection. Power cannot be restored to an installation disconnected for more than 6 months without an AS/NZS 3019 certificate that it is suitable for continued use. And in leased premises, fittings in an installation that complies with AS/NZS 3019 are deemed electrically safe.

How often should a commercial installation be inspected?

How often depends on the age and condition of the installation, how hard it works, the environment, and what earlier inspections found. Industrial sites, damp or dusty areas and older buildings need checking more often. One insurer's checklist for building owners asks whether an electrician checks the electrical system at least annually, which is a sensible baseline to discuss with your insurer.

AS/NZS 3019 sets out how periodic assessment of an existing installation is done. Our report recommends the next inspection date, and the inspection can sit in a planned maintenance programme.

When should you book an electrical inspection?

Book an inspection when you need to know the condition of an installation you are responsible for but did not install. The common triggers are buying, leasing or taking over management of a building, a change of tenant or use, an insurer's request, a building that has stood empty, and damage from fire, flood or a serious fault. Older installations benefit from a baseline inspection too.

What is in the inspection report?

The report lists what we inspected and tested, the results, and each defect with its location and a priority, so you can see at a glance what must be fixed now, what should be planned, and what to monitor. It also notes anything we could not access or test, so the limits of the inspection are clear to you, your insurer or a buyer.

  • Immediate. Defects that make part of the installation electrically unsafe, which should be made safe or isolated straight away.
  • Plan. Items that need repair or upgrade within a set period, such as missing RCD protection or deteriorated cables.
  • Monitor. Items that are acceptable now but should be checked again at the next inspection.

Repairs that are general or high-risk prescribed electrical work are certified with a Certificate of Compliance.

How long does an electrical inspection take?

A visual inspection of a small tenancy can take a couple of hours. A full test of a large building or an industrial site can take several days and is usually staged so that only part of the site is off at once. Time depends on the number of boards and circuits, access, and how much testing needs circuits isolated.

We agree the scope and any shutdowns with you in advance. Our office hours are Monday to Friday, 7.30am to 5.00pm; talk to us about out-of-hours work if daytime isolation would stop your business.

Frequently asked questions

What will fail an electrical inspection?

Common failures are exposed live parts, damaged cables, missing or faulty RCD protection, poor earthing, overheating or arcing at connections, overloaded circuits, incorrect switchboard labelling, and fittings unsuitable for their environment, such as unprotected fittings in wet areas. Each is listed in the report with its priority and the fix needed.

Is an electrical inspection the same as a Certificate of Compliance?

No. A Certificate of Compliance (CoC) is issued for prescribed electrical work, such as a new circuit or switchboard, to certify that the work is safe and complies. An electrical inspection assesses the condition of an existing installation and results in a report. If the inspection leads to repairs, repairs that are general or high-risk prescribed electrical work get a CoC.

Who can carry out an electrical inspection in New Zealand?

Use a licensed electrical worker. Certifying prescribed electrical work is itself prescribed electrical work under the Electricity (Safety) Regulations 2010, and some periodic assessments, such as those for hazardous areas, may only be done by people with the competencies the relevant standard sets. You can check any electrician's licence on the public register.