Phase Safe Electrical inspects electrical equipment and installations in hazardous areas: the parts of a site where flammable gas, vapour or combustible dust can form an explosive atmosphere. We inspect and report against AS/NZS 60079.17, the standard the Electricity (Safety) Regulations 2010 name for these installations, and our electricians fix what the inspection finds. We work for commercial and industrial clients across New Zealand, from bases in Wellington and Auckland.
What is a hazardous area inspection?
A hazardous area inspection checks that the electrical equipment installed where an explosive atmosphere can occur is still suitable for that location and in a condition that cannot ignite it. The inspector compares each item with the site's area classification, checks its markings, enclosure, seals, cable entries and earthing, and records every defect. The result is a report that shows what is safe, what is not, and what to fix first.
The Electricity (Safety) Regulations 2010 define a hazardous area as one where an explosive atmosphere needs special precautions for the construction, installation and use of electrical equipment. Ordinary fittings can spark or run hot enough to ignite gas or dust, so equipment there is built to a protection concept, such as a flameproof enclosure or intrinsically safe circuit. An inspection confirms that protection still works.
Which sites need hazardous area inspections?
Any site with a classified hazardous area needs the electrical installation in that area inspected. That usually means places where flammable liquids, gases or combustible dusts are stored, handled or processed. Whether your site has a hazardous area depends on its classification, not its industry, but the sites below commonly do. If you are not sure, the classification drawings for your site will show it.
- Fuel. Service stations, fuel depots, fleet refuelling and bulk storage. WorkSafe notes that at service stations hazardous areas usually apply to petrol and LPG, not diesel.
- Chemicals and solvents. Chemical stores, decanting areas and plants using flammable solvents.
- Paint. Spray booths, mixing rooms and drying ovens.
- Food and grain dust. Flour mills, grain silos, sugar, feed and powder processing.
- Wastewater. Treatment plants and pump stations where methane can collect.
- Gas. LPG cylinder stores, filling areas and gas metering sites.
- Manufacturing and storage. Coating lines, woodworking dust and warehouses holding flammable goods.
What New Zealand law requires for hazardous areas
Two sets of regulations work together. The Health and Safety at Work (Hazardous Substances) Regulations 2017 require a business using certain flammable gases, aerosols and liquids to establish a hazardous area that complies with AS/NZS 60079.10.1:2022. The Electricity (Safety) Regulations 2010 then control the electrical installation inside that area, from how it is installed to how often it is assessed.
The key electrical requirements are:
- Installation. It must comply with Part 2 of AS/NZS 3000 and with AS/NZS 60079.14, the standard for design, selection, erection and initial inspection (regulation 60).
- High-risk work. Installing or altering it is high-risk prescribed electrical work (regulation 6A), which must be inspected and certified with a Certificate of Compliance and record of inspection (regulations 65 and 70).
- Periodic assessment. Owners and operators must have low voltage installations in hazardous areas periodically assessed in accordance with AS/NZS 60079.17, by a person with the competencies that standard refers to, who gives you a record of assessment (regulation 75). Keeping the installation in service without it is an offence.
For how zones are set and why they matter, see our guide to hazardous area classification and zones.
Initial, periodic and sample inspections
AS/NZS 60079.17 expects an initial inspection of every hazardous area installation, followed either by regular periodic inspections or by continuous supervision by skilled personnel. Sample inspections cover a proportion of the equipment and help show whether the inspection interval suits the conditions on site. Each inspection is carried out to a grade, from visual through close to detailed, depending on how far the inspector needs to go.
| Type | When it happens | What it covers |
|---|---|---|
| Initial | Before new or altered equipment goes into service | Confirms the equipment and installation suit the area classification, as installed |
| Periodic | At regular intervals for the life of the installation | Checks condition, suitability and unauthorised changes across the installation |
| Sample | Between or alongside periodic inspections | A proportion of the equipment, to check how quickly conditions on site cause deterioration |
The grades build on each other. A visual inspection finds defects you can see without tools, such as missing bolts or damaged cables. A close inspection adds checks that need access equipment and tools, without opening the equipment. A detailed inspection opens enclosures and uses test equipment. Continuous supervision suits large sites with skilled staff always on hand.
How often is hazardous area equipment inspected?
The regulations do not set a single interval for hazardous areas. Regulation 75 requires assessment in accordance with AS/NZS 60079.17, which ties frequency to the type of equipment, the conditions it works in, and the results of earlier inspections. Equipment exposed to corrosion, vibration, heat or dust usually needs shorter intervals, and consistently good results can support longer ones.
For dust areas, housekeeping also affects the inspection and maintenance needed. WorkSafe's guidance for service stations refers to reports from four-yearly inspections. Whatever interval suits your site should be written into the dossier, so the next due date is clear.
What we check during a hazardous area inspection
We start from your area classification drawings and work through every item of electrical equipment inside the zones. The checks below are typical of a hazardous area inspection. The grade agreed for the inspection decides how many of them apply to each item, and the report records which grade was used.
- Suitability. The equipment's Ex marking matches the zone, gas or dust group and temperature class on the classification.
- Enclosures. Covers, bolts, gaskets and flamepaths are complete and undamaged, with no unauthorised modifications.
- Cable entries. Glands and stopping plugs are the right type and are tight and sealed.
- Earthing and bonding. Earth connections and bonding are in place and sound.
- Intrinsically safe circuits. Barriers, isolators and cabling are as designed, kept separate from other circuits.
- Environment and changes. Corrosion, water entry, vibration, dust build-up, and new or moved equipment the drawings do not show.
We do not change your classification. If the site no longer matches the drawings, we report it for review.
Records and the hazardous area dossier
A hazardous area dossier, also called a verification dossier, is the set of records that shows your installation is suitable for its zones and has been inspected. It usually holds the classification drawings, an equipment register with each item's certificate and marking, installation and initial inspection records, and every inspection report since. Inspectors work from it, and it shows a regulator or certifier how the installation is managed.
Under regulation 75, the person who completes a periodic assessment must give you a record of assessment stating the standard used, and keep a copy for at least 3 years or send it to WorkSafe. At service stations, WorkSafe notes the reports must be available for the location compliance certificate assessment. Our report and an updated equipment list go into your dossier, and we flag any missing records.
What happens after the inspection?
After the inspection you receive a report that lists each defect against the equipment register, with its location, what is wrong and how urgent it is. Items that could ignite an explosive atmosphere come first. Our electricians then quote for and carry out the repairs, and the dossier is updated so the next inspection starts from an accurate record of the installation.
- Rectification. Replacing glands and seals, restoring earthing, replacing damaged fittings and removing unsuitable equipment.
- Replacement equipment. Selected to match the zone, gas or dust group and temperature class.
- Repair or replace. Repair and overhaul of explosion-protected equipment has its own standard, AS/NZS 3800, so we tell you when an item should be replaced or sent for repair rather than patched on site.
- Certification. The work is high-risk prescribed electrical work, so it is inspected and certified.
Faults between inspections can go to our fault finding and 24/7 call-outs team, recurring checks can sit in a planned maintenance programme, and our commercial electrical inspections cover the installation outside the zones in the same visit.
Hazardous area guides
Our guide explains how gas and dust zones are set and why the zone decides which electrical equipment can be installed there. It helps you read classification drawings and inspection reports, and brief contractors clearly.
- Hazardous area classification and zonesWhat gas and dust zones mean and how classification decides the equipment you can use.
Frequently asked questions
Who is responsible for hazardous area inspections?
The owner or operator of the installation. Regulation 75 of the Electricity (Safety) Regulations 2010 puts the duty on owners and operators of low voltage installations in hazardous areas to have them periodically assessed in accordance with AS/NZS 60079.17. Keeping the installation in service without that assessment is an offence. The business that manages the site also has duties under the Health and Safety at Work Act 2015.
Can any electrician work in a hazardous area?
No. Installing or altering an installation in a hazardous area is high-risk prescribed electrical work, which must be inspected and certified. Periodic assessments may only be done by a person with the competencies referred to in AS/NZS 60079.17. Ask any contractor, including us, how the person doing your work meets those requirements before work starts.
Does a diesel tank need a hazardous area?
Usually not at a service station. WorkSafe's guidance says diesel is less flammable than petrol and does not require a hazardous area there, while petrol and LPG usually do. Other sites can differ, for example where diesel is heated or sprayed, so the classification for your site decides. If petrol, LPG or solvents are stored nearby, those areas will need classifying.
Sources
- Electricity (Safety) Regulations 2010, regulation 4 (hazardous area), regulations 6A, 60, 65, 70 and 75, and Schedule 2 (New Zealand Legislation)
- Health and Safety at Work (Hazardous Substances) Regulations 2017, regulations 10.6 and 10.7 (New Zealand Legislation)
- Health and Safety at Work Act 2015, sections 36 and 37 (New Zealand Legislation)
- Keeping your service station compliant with the hazardous substances regulations (WorkSafe)
- AS/NZS 60079.17:2017 Explosive atmospheres, Part 17: Electrical installations inspection and maintenance (Standards New Zealand)
- AS/NZS 60079.14:2022 Explosive atmospheres, Part 14: Design, selection, erection and initial inspection (Standards New Zealand)
- BS EN 60079-17:2014, scope: initial inspection, then periodic inspection or continuous supervision (BSI)
- BS EN 60079-17:2007, contents: grades of inspection, visual, close and detailed (BSI)