Test and tag is the routine inspection and testing of plug-in equipment, with a tag that shows who tested it, when, and when it is next due. Phase Safe provides test and tag for workplaces across New Zealand, from bases in Wellington and Auckland: offices, retail, workshops, warehouses and construction sites. Testing is carried out by certified testers, every item goes on a register, and you get a report for audits and a reminder when the next round is due.
What is test and tag?
Test and tag is the in-service safety inspection and testing of electrical equipment that connects to the supply through a flexible cord. The method comes from AS/NZS 3760, the joint Australian and New Zealand standard, now in its 2022 edition. Each item is inspected, put through electrical tests, then labelled with the test date and the date it is next due. You will also hear it called portable appliance testing, or PAT testing.
A tag is a snapshot: it shows the item was safe on the day it was tested, not that the lead survived a pallet jack the following week. WorkSafe makes the same point, so test and tag works best alongside quick checks by the people using the equipment.
Most faults are visible. Standards New Zealand reports that experience shows more than 90% of defects can be picked up by visual inspection, which is why a good test and tag visit spends as much time looking at plugs, cords and casings as it does on the tester.
What equipment gets tested and tagged?
Anything in your workplace that plugs into a socket through a flexible cord is in scope for test and tag. That includes the equipment people use every day without thinking about it, and the leads and boards that feed it. Equipment that is wired permanently into the building is part of the fixed installation instead, and it is checked differently by an electrician.
On a typical commercial or industrial site, that means:
- Portable appliances: heaters, fans, kettles, microwaves, fridges, vacuum cleaners and floor polishers
- Office equipment: computers, monitors, printers, chargers and plug-pack power supplies
- Extension leads and cord sets, including the detachable IEC leads on computers and monitors
- Power boards (multi-boards)
- Portable RCDs, whether they plug into a socket or are built into a lead
- Power tools: drills, grinders, saws, sanders, and the chargers for battery tools
- Kitchen and staffroom equipment: toasters, sandwich presses, urns, dishwashers on a plug, commercial kitchen appliances

How does a test and tag visit run on a working site?
A test and tag visit works through your site one area at a time, so people can keep working. Each item is unplugged only for its own inspection and test, then goes straight back into service with a new tag. Anything that fails is taken out of use on the spot, not left for later. Before we start, we agree the order of areas with you and flag anything that cannot be switched off.
Each visit follows the same steps:
- Inventory and register. Every item gets an identifier and goes on the register with a description and location. On a repeat visit we work from the existing register and add anything new.
- Visual inspection. Plug pins, cord, cord grip, casing, guards and any signs of heat damage, crushing or DIY repairs.
- Electrical tests. Using a portable appliance tester, the tests cover what AS/NZS 3760 asks for the type of equipment, such as earth continuity on earthed (Class I) equipment and insulation or leakage current tests.
- Tag. A durable tag goes on the cord near the plug, showing who tested it, the test date and the retest date.
- Failed items. Anything that fails is tagged out of service, removed from use and listed in the report, so you can decide whether to repair or replace it.
- Report and register. You receive the updated register and a report of what was tested, what passed and what failed.
Our hours are Mon–Fri 7.30am–5.00pm. If an area can only be tested when it is closed, talk to us about after-hours work.
Which workplaces need test and tag?
Any workplace where staff, contractors or hirers use plug-in equipment you own can use test and tag to show that equipment is being kept safe. What changes from one workplace to the next is the environment: the harder the conditions on cords and tools, the shorter the gap between tests. A desk computer in a quiet office needs far less attention than a grinder in a workshop.
The workplaces we test and tag include:
- Offices: mostly low-risk desk equipment, plus the heaters, leads and kitchen appliances that get moved and flexed every day
- Retail: shop-floor displays, back-of-house equipment and staffroom appliances
- Workshops and light manufacturing: power tools and equipment working in dust, vibration and heat
- Warehouses and storage facilities: chargers, heaters, leads run across floors, and equipment in cold or damp areas
- Construction sites: power tools, leads and portable outlet assemblies under AS/NZS 3012, the construction and demolition site standard, which sets its own expectations for site electrical equipment
If you run several sites, we can set up a multi-site testing plan so each location is tested on the right cycle and reported in the same format.
Records, reports and reminders
The register and report are what you show an auditor, a client or WorkSafe when you are asked how you manage electrical equipment. WorkSafe recommends documenting results whenever equipment is tested or inspected. After each visit you get a detailed report for record-keeping and audit purposes, and we send a reminder when the next round is due, so retesting does not depend on someone remembering.
Do you test RCDs as part of test and tag?
Yes. AS/NZS 3760 covers RCDs (residual current devices, also called safety switches) as well as equipment, which is why its full title ends "and RCDs". Portable RCDs, including those built into leads and portable outlet assemblies, are tested to check they trip within the required time. Users should also press the test button regularly: on construction sites, WorkSafe says every day before use.
RCDs fixed in your switchboards are part of the building's installation. If you want those tested at the same visit, tell us when you ask for a quote.
How much does test and tag cost?
Test and tag is usually priced per item, plus a call-out fee or minimum charge per visit. Published New Zealand price lists from 2025–26 mostly sit between about $2 and $6 per item excluding GST for standard volumes, with larger sites paying less per item and small jobs paying a minimum. Phase Safe quotes each site once we know how many items there are and how spread out they are.
The test and tag cost guide covers the published figures, what moves the price and how to keep it down.
Is test and tag a legal requirement in NZ?
Not as such. WorkSafe and the Electrical Workers Registration Board both say test and tag is not mandatory. What the law requires is that equipment is electrically safe and kept that way. Under the Electricity (Safety) Regulations 2010, equipment used by employees or contractors is deemed electrically safe if it carries a current tag issued under AS/NZS 3760, which is why most workplaces choose to test and tag.
Your wider duty as a PCBU sits in the Health and Safety at Work Act 2015. The test and tag requirements guide explains the regulations, recommended intervals, tag colours and who can do the testing.
What happens to equipment that fails?
A failed item is taken out of use straight away and listed in your report. From there it is a repair or replace decision. Only a registered electrical worker can fix the faults testing reveals, so a test and tag provider without electricians has to hand the repair to someone else. Phase Safe is an electrical contractor, so we can quote the repair at the same time.
Testing sometimes points to a problem beyond the appliance: an RCD that will not trip, a socket that is damaged, or a circuit that keeps tripping. Those faults are in the fixed wiring, and our electricians can repair them, either as a one-off job or as part of planned electrical maintenance.
Test and tag guides
- Test and tag costPer-item prices, minimums and how to keep the cost down.
- Test and tag rules in NZThe law, AS/NZS 3760 intervals, tag colours and who can do it.
Frequently asked questions
Can anyone do test and tag?
Not anyone, but it does not have to be an electrician. WorkSafe says the person doing it must have the knowledge and skills to do the task correctly and understand the standards involved, and does not need to be a registered electrical worker. A business can train a worker and buy a tester, or hire a third party. Only a registered electrical worker can repair faults the testing finds.
How long does a test and tag last?
A tag lasts until the retest date written on it. The tester sets that date from the environment the equipment works in, using the intervals in AS/NZS 3760: shorter in workshops, construction sites and hire fleets, longer for equipment that sits still in an office. A tag only confirms the item was safe when tested, so damaged equipment should be withdrawn even if its tag is current.
What is the standard for electrical testing in New Zealand?
For in-service equipment, the standard is AS/NZS 3760:2022, In-service safety inspection and testing of electrical equipment and RCDs. It is a joint Australian and New Zealand standard published by Standards New Zealand and referenced in the Electricity (Safety) Regulations 2010. Construction and demolition sites also follow AS/NZS 3012, and repaired appliances are tested under AS/NZS 5762.
What does an electrical test tag look like?
A test tag is a small durable label wrapped around the cord near the plug. It typically shows the name of the person or company that tested the item, the test date, the next test date and a reference to AS/NZS 3760. Many tags are colour-coded by period, but in New Zealand the colour is a workplace convention: the dates on the tag are what count.
Sources
- WorkSafe: Testing and tagging electrical appliances
- EWRB: Testing and tagging electrical appliances
- Electricity (Safety) Regulations 2010, regulation 26
- WorkSafe: Electrical safety on small construction sites
- Standards New Zealand: AS/NZS 3760:2022
- Standards New Zealand: Corded and electric? Test it and tag it with AS/NZS 3760