Many commercial HVAC breakdowns are electrical faults: a unit with no power, a fan that trips its breaker, a drive showing a fault code, or controls that have stopped calling for heating or cooling. Phase Safe troubleshoots the electrical side of heating, ventilation and air conditioning for commercial and industrial buildings across New Zealand, covering supply, protection, controls, motors and variable speed drives. Where the fault is in the refrigeration system, we bring in specialist HVAC subcontractors.
Is an HVAC technician the same as an electrician?
No. HVAC technicians work on the mechanical and refrigeration side: refrigerant, compressors, coils, airflow and commissioning. Electricians work on the supply, wiring, protection and control circuits that power the plant. In New Zealand, prescribed electrical work may only be done by people authorised under the Electricity Act 1992, such as licensed electrical workers. Many HVAC faults sit on the boundary, which is why the two trades often work together.
HVAC stands for heating, ventilation and air conditioning. On a commercial site that can mean rooftop packaged units, split and multi-split systems, air handling units, extract and supply fans, chillers and the pumps and controls that serve them. Each one depends on a sound electrical supply.
Which electrical faults stop HVAC systems?
The electrical faults we see most often on HVAC plant are loss of supply, protection that trips, failed motors, contactors and overload relays, variable speed drive faults, and control faults that stop a unit being told to run. Loose or heat-damaged terminations are common on rooftop plant, where vibration, weather and temperature swings work on connections all year.
| Symptom | Likely electrical cause | What we check |
|---|---|---|
| Unit completely dead | Lost supply, tripped breaker, blown fuse, failed isolator or control supply | Supply at the isolator and the board, control circuit supply |
| Breaker or RCD trips when the unit starts | Motor winding or insulation fault, damaged cable, failing compressor motor | Insulation resistance, motor windings, cable condition |
| Fans run but no heating or cooling | Control signal missing, contactor not pulling in, or a refrigeration fault | Controls and contactor; refrigeration faults referred to our HVAC specialists |
| Drive shows a fault and the fan or pump stops | Supply disturbance, motor or cable fault, drive overheating | Drive fault history, supply, motor and cabling, drive cooling |
| Trips at random, often on hot days | Loose terminations, overheating, phase imbalance, overload | Terminations, load on each phase, thermal scan of the board |
What do variable speed drives have to do with HVAC faults?
A variable speed drive (VSD), also called a variable frequency drive, controls the speed of a motor by changing the frequency of its supply. In HVAC it lets fans and pumps run only as fast as the building needs, which saves energy. When a drive trips, the fan or pump it controls stops, and the drive's fault record is usually the first clue to why.
Drive trips often trace back to something outside the drive: a supply problem, a motor or cable fault, or a drive enclosure that is running too hot because its own cooling has failed. We check the supply, cabling and motor before deciding whether the drive itself needs repair or replacement.
When do you bring in an HVAC specialist?
We bring in specialist HVAC subcontractors when the fault is in the refrigeration system or mechanical plant rather than the electrics: refrigerant leaks, gas charging, compressor mechanical failures, coils, refrigerant pipework and airflow balancing. Our electricians handle the supply, protection, controls, motors and drives. You deal with Phase Safe for the whole job, and we coordinate the specialist work where the job needs it.
If we find the electrical side is sound, we say so, so you aren't paying an electrician to chase a refrigeration fault.
Is air conditioning part of a building's compliance schedule?
It can be. Mechanical ventilation or air conditioning systems are one of the specified systems listed in Schedule 1 of the Building (Specified Systems, Change the Use, and Earthquake-prone Buildings) Regulations 2005. If they are on your building's compliance schedule, they must be inspected, maintained and reported on as the schedule sets out, and the building warrant of fitness relies on that work being done each year.
Our BWOF and IQP inspections page explains how compliance schedule work fits together. Tell us which specified systems are on your compliance schedule and we'll confirm what we inspect.
How can you reduce HVAC breakdowns?
Most electrical HVAC failures give some warning: a connection that runs hotter each year, a motor whose insulation is deteriorating, a drive that trips more often. Including HVAC boards, motor connections and drives in planned and predictive maintenance catches those signs early. A thermal scan of the boards that feed HVAC plant, done while the plant is under load, is one of the quickest ways to find them.
We work on HVAC in commercial and industrial buildings only, such as offices, retail, warehouses, workshops and industrial plant. We do no residential work.
Frequently asked questions
What is HVAC in electrical terms?
In electrical terms, HVAC is a group of loads and controls: fan, pump and compressor motors, heaters, drives, contactors and control circuits, often fed from their own distribution board or motor control panel. The electrical side covers everything that supplies, protects, switches and controls that plant. The refrigeration side, including refrigerant and compressor mechanics, is specialist HVAC work.
Can an HVAC technician do electrical work?
Only within the limits of what they are authorised to do. Under section 74 of the Electricity Act 1992, prescribed electrical work may only be done by people authorised under a current practising licence or another licence the Act allows. If you aren't sure who can do a particular repair, ask to see the licence or check the Electrical Workers Registration Board public register.
Why does my air conditioning keep tripping the breaker?
A unit that keeps tripping its breaker or RCD usually has a fault in a motor, a damaged cable, moisture in a connection, an overloaded circuit or failing protection. Repeated resets can make the damage worse. Leave it switched off and call us: we test the circuit and the unit's electrical parts, and bring in an HVAC specialist if the cause turns out to be mechanical.
Do you service air conditioning units?
We service the electrical parts: supply, isolators, protection, motors, contactors, drives and controls. Refrigeration servicing, such as refrigerant checks and gas charging, is done by specialist HVAC subcontractors where the job requires it. That way one call covers the whole fault, and each part of the work is done by the right trade.
Sources
- Electricity Act 1992, section 74: who may do prescribed electrical work (legislation.govt.nz)
- Building (Specified Systems, Change the Use, and Earthquake-prone Buildings) Regulations 2005, Schedule 1: specified systems (legislation.govt.nz)
- Building Act 2004, sections 103 and 108: compliance schedules and the building warrant of fitness (legislation.govt.nz)
- About licences and the Electrical Worker Public Register (Electrical Workers Registration Board)