What is a switchboard, and how is it different from a distribution board?

The parts of a building's power distribution, in plain terms, so you know what you're asking for.

Updated 10 November 2026

A switchboard is the enclosure where a building's electricity supply is switched, protected and divided into circuits. The main switchboard takes the supply from the network; distribution boards and sub-boards take power from it and feed the circuits on each floor, tenancy or work area. Knowing which is which helps you brief an electrician clearly. For upgrade and replacement work, see our commercial switchboard upgrades page.

What is a switchboard?

A switchboard is an assembly of switches, protective devices and connections, mounted in an enclosure, that controls how electricity reaches the circuits in a building. It lets you isolate the supply, protects cables and people from faults, and splits the incoming power into separate circuits. In New Zealand, "switchboard" is the everyday word for any of these boards, from a large main board to a small one in a tenancy.

Every commercial building has at least one. In a small shop it may be a single board with a few dozen circuits. In a larger office block or industrial site, there is a main switchboard near the point of supply and a network of smaller boards spread through the building, each fed by its own cable, called a sub-main.

Switchboard vs distribution board vs sub-board

The difference is mostly about position in the building's power distribution. The main switchboard is where the supply from the lines company arrives and is first switched and protected. A distribution board is fed from the main switchboard and supplies the final circuits in one area. A sub-board is any board fed from another board, so most distribution boards are also sub-boards.

Board Where it sits What it does
Main switchboard Closest to the point of supply, often in a plant room or at the meter position Holds the main switch and main protection, often the meters, and feeds the sub-mains
Distribution board On each floor, in each tenancy or in a work area Splits a sub-main into final circuits for lighting, power outlets and equipment
Sub-board Anywhere downstream of another board A local board for a workshop, machine area, kitchen or outbuilding
Meter board At the supply point or in a meter room Holds the revenue meters, and on larger supplies the current transformers that feed them

In a single-tenancy building, the main switchboard and the distribution board are often the same board. The names start to matter when a tenancy changes or new equipment arrives, because the work might be on a local distribution board, on the main switchboard, or on both.

Switchboard vs switchgear

Switchgear is the heavier switching and protection equipment used to control larger amounts of power, such as large air circuit breakers, fused switches and isolators. A switchboard is the assembly that houses equipment like this. A large main switchboard contains low-voltage switchgear; a small distribution board contains small circuit breakers and RCDs that people rarely call switchgear.

You will mostly hear "switchgear" on bigger sites: large office buildings, industrial plants and anywhere with its own transformer. High-voltage switchgear on the supply side usually belongs to the lines company or is a specialist field of its own. For most commercial premises, the equipment you deal with is the low-voltage main switchboard and the distribution boards it feeds.

What is another name for a switchboard?

Common alternative names are distribution board, DB, fuse box, breaker box and electrical panel. In the United States, "panelboard" or "breaker panel" is roughly what New Zealand calls a distribution board, while an American "switchboard" usually means a larger, floor-standing assembly. In the United Kingdom, a small board is often called a consumer unit.

"Fuse box" is a leftover from the days when boards used rewireable fuses rather than circuit breakers. If your board still has fuse wire in ceramic holders, it is an old board, and our guide on whether your business needs a switchboard upgrade explains why that matters.

Types of switchboards in commercial buildings

Switchboards are grouped by how they are mounted, what enclosure they use, what supply they take and what they hold. The main choices are surface or flush mounting, the enclosure and its IP rating, single-phase or three-phase supply, and whether the board includes metering. The right combination depends on where the board sits, what it feeds and who needs to get to it.

  • Surface-mounted boards. Fixed to the face of a wall. Common in plant rooms, warehouses and workshops, where they are easy to reach, extend and work on.
  • Flush-mounted boards. Recessed into a wall so the door sits flush with the surface. A tidy choice for offices, shops and hospitality fitouts, but harder to enlarge later.
  • Free-standing boards. Floor-standing cubicles used for larger main switchboards, with room for large devices, busbars and cable entries.
  • Enclosures and IP ratings. Enclosures are usually steel or tough plastic. The IP code rates protection against solid objects and dust (first digit) and water (second digit). Outdoor, dusty or wash-down areas need a higher rating than a dry office corridor.
  • Single-phase and three-phase. Single-phase boards suit offices and small shops. Three-phase boards supply machinery, large motors, commercial kitchens and larger heating and cooling equipment.
  • Meter boards. Hold the revenue meters for the site or each tenancy. Larger supplies are metered through current transformers rather than directly.

Main components of a switchboard

Most commercial switchboards contain the same core parts: a main switch, circuit breakers, RCDs or RCBOs, often surge protection, and busbars, plus neutral and earth connections and, on main boards, metering. Each part has a specific job, and knowing them makes an electrician's quote much easier to read.

  • Main switch. Isolates everything the board supplies. On a main switchboard it is the first point where the building's supply can be turned off.
  • Circuit breakers. Switch off automatically when a circuit is overloaded or short-circuited, protecting the cables. Larger moulded-case breakers protect sub-mains and big loads.
  • RCDs. Residual current devices trip when current leaks to earth, for example through a person, and are the main protection against electric shock.
  • RCBOs. Combine a circuit breaker and an RCD in one device for a single circuit, so a fault on one circuit does not cut power to others.
  • Surge protection devices. Limit voltage spikes from lightning or network switching that can damage electronic equipment.
  • Busbars. Solid copper or aluminium bars that carry current from the main switch to the protective devices.
  • Neutral and earth bars. Connection points for the neutral and earth conductors. The main switchboard also holds the link between earth and neutral for the building's earthing system.

Switchboard labelling

Every circuit on a switchboard should be clearly labelled, so anyone isolating power picks the right device first time. The wiring rules include requirements for identifying switchboard equipment, such as main switches and the circuits each device controls. Good labelling also includes a circuit schedule that matches what is actually installed.

Labels drift out of date after fitouts, tenancy changes and quick repairs, and a wrong label is a real hazard when someone switches off a circuit to work on it. If your labels are missing, handwritten or no longer match the building, ask for them to be checked and corrected during the next switchboard job or maintenance visit.

Frequently asked questions

What is the difference between a switchboard and a panelboard?

"Panelboard" is a North American term. There, a panelboard is a smaller, usually wall-mounted board that feeds final circuits, close to what New Zealand calls a distribution board. A US switchboard is a larger, floor-standing assembly closer to a main switchboard. In New Zealand, "switchboard" covers both, and electricians separate them as main switchboards, distribution boards and sub-boards.

What are the different types of switchboards?

Switchboards are usually described by their role and their construction. By role, there are main switchboards, distribution boards, sub-boards and meter boards. By construction, they are surface-mounted, flush-mounted or free-standing, in metal or plastic enclosures with an IP rating to suit the location, and wired for single-phase or three-phase supply.

Is a distribution board the same as a switchboard?

A distribution board is a type of switchboard. The term is normally used for boards that take power from the main switchboard and split it into final circuits for one area, such as a floor, a tenancy or a workshop. In a small single-tenancy building, one board can do both jobs, so people often use the two names for the same thing.

How is a switchboard built?

A commercial switchboard is designed around the building's supply, the loads it feeds and the space available, then built from an enclosure, busbars and protective devices sized for those loads. Installing, altering or connecting it is prescribed electrical work, which only licensed electrical workers may do, followed by testing and certification. Larger main switchboards are often made by specialist switchboard manufacturers.

What is a main switchboard?

The main switchboard is the board closest to where the electricity supply enters the building. It holds the main switch that isolates the whole installation, the main protective devices and often the meters, and it feeds the sub-mains to every distribution board. Work that connects the mains or the main earthing at this board is classed as high-risk prescribed electrical work and must be inspected.